Files
heating-mpc-ha/custom_components/heating_mpc/strings.json
T
buzeraandClaude Opus 5.5 46587af8a3 Introduce thermal zones as config subentries
Each temperature sensor used to be its own "room", so a room with two
sensors counted twice and comfort importance was tied to sensors.

zones.py adds Zone: a name, one or more sensors with sensor weights, a
comfort weight, an optional target offset and adjacent zones (made
symmetric). Sensor weights only combine readings; comfort weights only
steer the MPC; neither touches the learned thermal coefficients.

Zones are config subentries (HA's native "Add zone" / edit / delete on
the integration page), with validation that a sensor belongs to one
zone and is not an outdoor source, and a sensor-weight step for
multi-sensor zones. Initial setup still asks for room sensors and
weights and creates one zone per sensor. Configure no longer asks for
rooms or weights.

Config entry version 3. Migrating from 2 turns each room sensor into a
one-sensor zone with its comfort weight and the sensor's entity ID as
the zone key, so learned models, forecast entities (now linked to their
zone, so deleting a zone removes them) and accuracy statistics carry
over. Older versions cannot load a version 3 entry; rolling back needs
the HA backup.

A zone learns only across polls that used the same sensors (a sensor
dropping out shifts the mean by its offset); the new poll outcome
"sensors_changed" reports this. Status renames: input_quality.zones
(per-sensor detail nested), excluded_zones, retired_zone_models; adds
zone_names. Invalid stored comfort weights now fall back to 1.0, so the
invalid_weights status is gone.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-27 02:32:11 +02:00

177 lines
8.9 KiB
JSON
Raw Blame History

This file contains ambiguous Unicode characters
This file contains Unicode characters that might be confused with other characters. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.
{
"title": "Heating MPC",
"config": {
"step": {
"user": {
"title": "Heating MPC — room inputs",
"description": "Choose thermostat, read-only relay and room sensors. This integration NEVER commands the heater.",
"data": {
"climate_entity": "Existing Generic Thermostat",
"heater_entity": "Physical heating switch (read-only)",
"room_entities": "Individual room temperature sensors",
"room_max_age_minutes": "Maximum room sensor report age (minutes)",
"weather_max_age_minutes": "Maximum weather sensor report age (minutes)",
"room_stale_use_last_value": "Keep using the last value of a room sensor that stopped reporting"
},
"data_description": {
"room_stale_use_last_value": "Off: a room sensor older than its report-age limit is left out and the other rooms are re-weighted. On: its last value is still used, for up to 24 hours without a report; for sensors that report only when the value changes. Unavailable or invalid room sensors are always left out. Nothing pauses unless no room is usable."
}
},
"weather": {
"title": "Primary weather sources",
"description": "Choose as many sensors per metric as needed and arrange them in priority order. If the preferred source is unavailable, the next one is used automatically. Outdoor temperature is mandatory; wind and cloud coverage are diagnostic-only in this version.",
"data": {
"outside_temperature_sources": "Outdoor temperature sources (ordered: preferred first)",
"outside_wind_sources": "Wind speed sources (optional)",
"outside_clouds_sources": "Cloud coverage sources (optional)"
}
},
"weather_extra": {
"title": "Additional weather sources",
"description": "Additional weather inputs are optional and used only for comparison/diagnostics in v0.2; they do not yet change MPC predictions.",
"data": {
"outside_humidity_sources": "Outdoor humidity sources (optional)",
"outside_feelslike_sources": "Feels-like temperature sources (optional)",
"outside_pressure_sources": "Atmospheric pressure sources (optional)",
"outside_visibility_sources": "Visibility sources (optional)",
"outside_rain_sources": "Rain sources (optional)",
"outside_snow_sources": "Snow sources (optional)"
}
},
"weights": {
"title": "Room priorities",
"description": "Each selected sensor becomes its own zone with this comfort weight. Later, group the sensors of one room into one zone with Add zone or by editing a zone."
}
},
"error": {
"invalid_rooms": "Select 1–12 distinct room sensors.",
"invalid_weather": "Select at least one outdoor temperature sensor, distinct from room sensors."
},
"abort": {
"already_configured": "Heating MPC is already configured."
}
},
"options": {
"step": {
"init": {
"title": "Heating MPC options",
"description": "Change room sensors and controller settings. This integration remains shadow-only.",
"data": {
"climate_entity": "Existing Generic Thermostat",
"heater_entity": "Physical heating switch (read-only)",
"horizon_minutes": "Prediction horizon (minutes)",
"minimum_on_minutes": "Minimum ON time (minutes)",
"minimum_off_minutes": "Minimum OFF time (minutes)",
"switching_cost": "Switching cost",
"heating_cost": "Heating runtime cost",
"comfort_band": "Comfort tolerance (°C)",
"room_max_age_minutes": "Maximum room sensor report age (minutes)",
"weather_max_age_minutes": "Maximum weather sensor report age (minutes)",
"room_stale_use_last_value": "Keep using the last value of a room sensor that stopped reporting"
},
"data_description": {
"room_stale_use_last_value": "Off: a room sensor older than its report-age limit is left out and the other rooms are re-weighted. On: its last value is still used, for up to 24 hours without a report; for sensors that report only when the value changes. Unavailable or invalid room sensors are always left out. Nothing pauses unless no room is usable."
}
},
"weather": {
"title": "Weather source priority",
"description": "Choose as many sensors per metric as needed and arrange them in priority order. If the preferred source is unavailable, the next one is used automatically. Outdoor temperature is mandatory; wind and cloud coverage are diagnostic-only in this version.",
"data": {
"outside_temperature_sources": "Outdoor temperature sources (ordered: preferred first)",
"outside_wind_sources": "Wind speed sources (optional)",
"outside_clouds_sources": "Cloud coverage sources (optional)"
}
},
"weather_extra": {
"title": "Additional weather sensors",
"description": "Additional weather inputs are optional and used only for comparison/diagnostics in v0.2; they do not yet change MPC predictions.",
"data": {
"outside_humidity_sources": "Outdoor humidity sources (optional)",
"outside_feelslike_sources": "Feels-like temperature sources (optional)",
"outside_pressure_sources": "Atmospheric pressure sources (optional)",
"outside_visibility_sources": "Visibility sources (optional)",
"outside_rain_sources": "Rain sources (optional)",
"outside_snow_sources": "Snow sources (optional)"
}
}
},
"error": {
"invalid_weather": "Select at least one outdoor temperature sensor, distinct from room sensors."
}
},
"entity": {
"sensor": {
"last_sample": {
"state": {
"waiting_for_inputs": "Waiting for inputs",
"first_sample": "First sample",
"sensors_changed": "Zone sensors changed",
"learned": "Learned",
"partly_rejected": "Partly rejected (outlier)",
"interval_out_of_range": "Irregular interval",
"relay_changed": "Relay switched",
"outside_source_changed": "Outdoor source changed",
"lag_uncertain": "Waiting for radiators to settle"
}
}
}
},
"config_subentries": {
"zone": {
"entry_type": "Zone",
"initiate_flow": {
"user": "Add zone",
"reconfigure": "Edit zone"
},
"step": {
"user": {
"title": "Thermal zone",
"description": "A room or area of the apartment. Sensor weights combine several sensors in one room; the comfort weight says how much the zone matters to the MPC. Neither changes the zone's learned thermal properties.",
"data": {
"name": "Name",
"sensors": "Temperature sensors",
"comfort_weight": "Comfort weight",
"target_offset": "Target offset (°C)",
"neighbors": "Adjacent zones (heat exchange)"
},
"data_description": {
"comfort_weight": "Relative importance for the MPC (0.1–10).",
"target_offset": "Added to the thermostat's target temperature for this zone.",
"neighbors": "Zones this one exchanges heat with, for example through a wall or an open door. The coefficient is learned only when the data supports it."
}
},
"sensor_weights": {
"title": "Sensor weights",
"description": "How much each sensor counts in the zone temperature (0.1–10)."
},
"reconfigure": {
"title": "Thermal zone",
"description": "A room or area of the apartment. Sensor weights combine several sensors in one room; the comfort weight says how much the zone matters to the MPC. Neither changes the zone's learned thermal properties.",
"data": {
"name": "Name",
"sensors": "Temperature sensors",
"comfort_weight": "Comfort weight",
"target_offset": "Target offset (°C)",
"neighbors": "Adjacent zones (heat exchange)"
},
"data_description": {
"comfort_weight": "Relative importance for the MPC (0.1–10).",
"target_offset": "Added to the thermostat's target temperature for this zone.",
"neighbors": "Zones this one exchanges heat with, for example through a wall or an open door. The coefficient is learned only when the data supports it."
}
}
},
"error": {
"zone_name_required": "Enter a name.",
"zone_sensors": "Choose 1–6 different sensors.",
"sensor_in_other_zone": "A chosen sensor already belongs to another zone.",
"sensor_is_weather_source": "A chosen sensor is used as an outdoor temperature source.",
"too_many_zones": "At most 12 zones are supported."
},
"abort": {
"reconfigure_successful": "The zone was updated."
}
}
}
}