buzeraandClaude Opus 5.5 a44163a57d Report how well the base coefficients are identified
The base layer (loss, heat, bias) showed values only, so a zone with weeks of
samples looked equally trustworthy whether or not the data ever varied its
inputs. Each base coefficient now reports a confidence from its own posterior
variance, as the extended and ventilation layers already did: it stays at 0
for `heat` while the relay never cycles and below 0.8 for `loss` and `bias`
while the indoor-outdoor difference is steady. Readiness is unchanged.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-27 03:49:13 +02:00
..