Author SHA1 Message Date
buzeraandClaude Opus 5.5 e62798dc4f Test power spikes, calm wind and restart of the new model layers
A single 5-minute +700 W spike moves the room's thermal response by at
most 0.2 kW and leaves the baseline at the persistent load. In calm air
the wind terms vanish while natural ventilation remains. Extended and
ventilation coefficients and heat-source baselines survive a restart
unchanged (no hour of baseline re-learning), and enabling an extra
ventilation term later keeps everything learned for the others.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-27 02:57:20 +02:00
buzeraandClaude Opus 5.5 ed8f9fe2e2 Model windows, ventilation, wind exposure and recovery
Opening a window adds heat exchange that the envelope model mistook for
poor insulation or a constant cooling bias.

windows.py adds windows as config subentries ("Add window"): a contact
sensor (optionally inverted; unknown/unavailable stays unknown, never
"closed"), its zone, the direction its outside faces (default 345°,
editable) and an opening factor. Each poll computes the share of the
interval each window was open (one change located by its timestamp, a
round trip is unknown), the wind exposure with proper circular angles
(meteorological "from" direction vs the window's facing) and a recovery
weight after closing that decays towards 0, pulling the air back
towards its pre-ventilation temperature. A bounded event log records
opening/closing, duration, temperatures before/lowest/at close/30 min
after, weather and other open windows.

While a zone's window is open, unknown or recovering, the base and
extended models skip it; a separate ventilation learner fits the
closed-window model's residual with natural exchange, wind speed, a
directional term bounded by the wind term (a leeward window still
ventilates), recovery, and optional gust excess and cross-ventilation
terms. Forecasts assume an open window closes after a configurable time
(default 15 min), then recovers. New poll outcome "ventilation".

Weather gains optional wind direction (degrees, 360 -> 0) and wind gust
sources with the same priorities and fallback; knots and ft/s accepted.

On a synthetic week with ventilation events every four hours and a
daily outdoor swing, the configured zone keeps loss/heat/bias close to
the truth and recovers the combined natural+wind effect within 15 %,
recovery within 15 % and direction within 30 %. The same data without
the window configured produces a -0.013 °C/5 min cooling bias and an
11 % inflated boiler effect.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-27 02:47:40 +02:00