buzeraandClaude Opus 5.5 ed8f9fe2e2 Model windows, ventilation, wind exposure and recovery
Opening a window adds heat exchange that the envelope model mistook for
poor insulation or a constant cooling bias.

windows.py adds windows as config subentries ("Add window"): a contact
sensor (optionally inverted; unknown/unavailable stays unknown, never
"closed"), its zone, the direction its outside faces (default 345°,
editable) and an opening factor. Each poll computes the share of the
interval each window was open (one change located by its timestamp, a
round trip is unknown), the wind exposure with proper circular angles
(meteorological "from" direction vs the window's facing) and a recovery
weight after closing that decays towards 0, pulling the air back
towards its pre-ventilation temperature. A bounded event log records
opening/closing, duration, temperatures before/lowest/at close/30 min
after, weather and other open windows.

While a zone's window is open, unknown or recovering, the base and
extended models skip it; a separate ventilation learner fits the
closed-window model's residual with natural exchange, wind speed, a
directional term bounded by the wind term (a leeward window still
ventilates), recovery, and optional gust excess and cross-ventilation
terms. Forecasts assume an open window closes after a configurable time
(default 15 min), then recovers. New poll outcome "ventilation".

Weather gains optional wind direction (degrees, 360 -> 0) and wind gust
sources with the same priorities and fallback; knots and ft/s accepted.

On a synthetic week with ventilation events every four hours and a
daily outdoor swing, the configured zone keeps loss/heat/bias close to
the truth and recovers the combined natural+wind effect within 15 %,
recovery within 15 % and direction within 30 %. The same data without
the window configured produces a -0.013 °C/5 min cooling bias and an
11 % inflated boiler effect.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-27 02:47:40 +02:00
buzeraandClaude Opus 5.5 00e70c612b Model electrical heat sources (UPS, gaming PC) per zone
Electrical equipment heats its room, and a gaming session can add
hundreds of watts, which the 3-parameter model attributed to the boiler
or the bias term.

heat_sources.py adds heat sources as config subentries ("Add heat
source"): an active-power sensor (W/kW; VA and % rejected), the zone,
the share that becomes heat, an automatic baseline (20th percentile of
24 h, so the persistent UPS load is not double counted with the bias
term) or a manual one, an optional "included in" parent (the UPS total
minus a separately measured PC, one level deep) and a first-order
thermal response time. The heat during each interval is the power held
from its start, like the radiator lag. After startup or an outage a
source's response must run two time constants before it counts as
settled.

zone_model.py layers each zone: the base model is kept unchanged as the
fallback and comparison, and an extended FeatureLearner adds "internal"
(kW above baseline after the response) and neighbour coupling for
adjacent zones. It learns only intervals where all its inputs are
known, and is used for forecasts once as trained as the base. The
optimizer accepts a multi-zone step model; forecasts let extra power
fade to baseline with a configurable half-life (default 30 min).

On a synthetic office with thermostat cycling and gaming sessions the
extended model recovers the electrical, boiler and loss coefficients
within 10 %. Status lists each source's power, effective power,
baseline, variable and responding heat; models show the extended
coefficients with confidence. Saved models gain optional zone_models
and heat_sources keys.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-27 02:39:18 +02:00
buzeraandClaude Opus 5.5 46587af8a3 Introduce thermal zones as config subentries
Each temperature sensor used to be its own "room", so a room with two
sensors counted twice and comfort importance was tied to sensors.

zones.py adds Zone: a name, one or more sensors with sensor weights, a
comfort weight, an optional target offset and adjacent zones (made
symmetric). Sensor weights only combine readings; comfort weights only
steer the MPC; neither touches the learned thermal coefficients.

Zones are config subentries (HA's native "Add zone" / edit / delete on
the integration page), with validation that a sensor belongs to one
zone and is not an outdoor source, and a sensor-weight step for
multi-sensor zones. Initial setup still asks for room sensors and
weights and creates one zone per sensor. Configure no longer asks for
rooms or weights.

Config entry version 3. Migrating from 2 turns each room sensor into a
one-sensor zone with its comfort weight and the sensor's entity ID as
the zone key, so learned models, forecast entities (now linked to their
zone, so deleting a zone removes them) and accuracy statistics carry
over. Older versions cannot load a version 3 entry; rolling back needs
the HA backup.

A zone learns only across polls that used the same sensors (a sensor
dropping out shifts the mean by its offset); the new poll outcome
"sensors_changed" reports this. Status renames: input_quality.zones
(per-sensor detail nested), excluded_zones, retired_zone_models; adds
zone_names. Invalid stored comfort weights now fall back to 1.0, so the
invalid_weights status is gone.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-27 02:32:11 +02:00
buzeraandClaude Opus 5.5 d2bd398a0f Show learning activity with Learning Progress and Last Sample sensors
During a first test the Status entity only said "learning" for the
first half hour (the radiator-lag wait after a restart), and the
attributes explaining why were hard to find. Add two sensors:

- Learning Progress (%): for the least trained room, the mean of its
  three readiness requirements (200 samples, 30 ON, 30 OFF), each capped
  at 100 %; 100 % means ready. Attributes show the counts.
- Last Sample: an enum of the last poll's learning outcome, with English
  and Romanian state names (e.g. "Waiting for radiators to settle"). Its
  history shows when learning happens.

Polls blocked by missing shared inputs now report waiting_for_inputs.
Readiness thresholds move to const.py.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-26 22:39:25 +02:00
buzeraandClaude Opus 5.5 3076beebfb Leave out unusable rooms instead of pausing; add keep-last-value option
A single stale, unavailable, missing or invalid room sensor paused
learning and forecasts for every room. That is not acceptable once the
MPC may control heating.

Now such a room is left out: the weighted temperature, learning and the
optimizer use the remaining rooms with their weights re-normalized, and
a room learns only across poll pairs where it was usable at both ends.
Readiness considers only the rooms used. Everything pauses only when no
room is usable or a shared input (relay, thermostat, outdoor
temperature) is missing.

A new setup/Configure checkbox, room_stale_use_last_value (default off),
keeps using a stale room sensor's last value instead, for sensors that
report only on change. It never applies to unavailable or invalid
sensors, or to a sensor silent for more than 24 hours.

Status adds excluded_rooms, weight_coverage and a per-room "used" flag.
English and Romanian labels and help text added.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>