Choosing room and weather freshness limits required knowing how long
each sensor normally goes without reporting, which HA does not show.
Add max_age_seconds_24h to every source in input_quality: the largest
report age seen at polls over the last 24 hours (hourly buckets, reset
on reload, underestimates by up to one poll interval).
input_quality and weather_comparison change every poll, so the Recorder
stored a new attribute row every five minutes. Mark them unrecorded;
they remain visible on the Status entity. Model coefficients and other
attributes are still recorded.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Saving wrote only the currently configured rooms, so removing a room in
Configure (even by accident) discarded its learned model at the next
save, and adding it back started from scratch.
Keep validated models of removed rooms (at most 24, oldest dropped
first) in an optional retired_learners payload key and restore them when
the room is added back. Payload schema_version stays 2: the key is
additive and older 0.2.x readers ignore it. Replacing the relay still
starts a fresh model, as before. Status lists retired_room_models.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Polling only sees the relay's current state and last change, so two or
more changes between polls (e.g. an on/off round trip) made the lag
estimate unknown and paused learning for about half an hour.
Subscribe to the relay's state changes (read-only) and integrate every
recorded change between polls. Because HA delivers these events one
loop iteration late, the current state stays authoritative and fills in
a change not yet recorded. Unknown periods (non on/off states, missed
transitions, event overflow) still restart the estimate with an
explicit error bound. Without the listener, behavior is as before.
HA skips unload callbacks after unexpected setup errors, so setup now
removes the listener itself on any failure and registers it for unload
only once setup succeeds.
Tested on HA Core 2025.12.0 and 2026.2.3.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Optional weather source fields used the current selection as the form
default. A cleared field that the frontend omits was refilled with the
old sources by voluptuous, and an options key missing from the
submission fell back to the original setup data. Optional providers
could therefore not be removed in the UI.
Pre-fill with suggested values instead, and save omitted optional lists
as empty so they override older entry data. No UI strings changed.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
A finished plan was discarded whenever any watched State object changed
during the save or calculation, including diagnostic-only weather
sensors and the thermostat's current_temperature/hvac_action. The
proposed-heat entity then went unavailable for five minutes without
cause. Compare only the values the prediction uses: room and outdoor
temperature states and units, thermostat mode and target, and relay
state and last change.
Also pass config_entry to the coordinator explicitly instead of relying
on HA's ContextVar fallback, which HA reports as deprecated usage.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
The lag proxy was reset to the new relay command at every relay change
and after any skipped interval, so it read 1.0 straight after ON and 0.0
straight after OFF. This disabled the lag model around every boiler
cycle: on a synthetic lagged plant cycled by a hysteresis thermostat the
learner's heat gain came out 34% low (0.079 vs 0.12) and the loss term
43% low, and the optimizer started post-transition plans from the wrong
lag.
Track the lag at every poll with a valid relay state, independently of
room sensors. Integrate a single change between polls at its
last_changed time. For ambiguous cases (round trip between polls, relay
outage, restart, clock jump) restart from time-in-state with an explicit
error half-width, and learn only once it is at most 0.1 (about 32 min
after an HA restart). The same synthetic test now learns 0.1195/0.00389
(true 0.12/0.004).
Expose heat_lag, heat_lag_uncertainty and sample_result on Status so
users can see why a poll was or was not learned. The HA test fixture
relay now has an hour-old timestamp; a new test covers a freshly
written relay state.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
With forgetting 0.999 and no heat excitation (summer, long OFF periods),
the heat-coefficient variance grew by 1/0.999 per sample without limit:
about 8.7e12 after 104 simulated OFF days. The first ON samples could
then swing coefficients to their bounds, and accumulated asymmetry
approached the absolute 1e-8 restore tolerance, past which a restart
silently reset the whole model.
Symmetrize P and bound its diagonal by the prior after every update
(row/column scaling keeps it positive definite). Restore uses a relative
round-off tolerance and applies the same bound, so wound-up v0.2.1
models load instead of being discarded. Payload schema is unchanged.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>