buzeraandClaude Opus 5.5 46587af8a3 Introduce thermal zones as config subentries
Each temperature sensor used to be its own "room", so a room with two
sensors counted twice and comfort importance was tied to sensors.

zones.py adds Zone: a name, one or more sensors with sensor weights, a
comfort weight, an optional target offset and adjacent zones (made
symmetric). Sensor weights only combine readings; comfort weights only
steer the MPC; neither touches the learned thermal coefficients.

Zones are config subentries (HA's native "Add zone" / edit / delete on
the integration page), with validation that a sensor belongs to one
zone and is not an outdoor source, and a sensor-weight step for
multi-sensor zones. Initial setup still asks for room sensors and
weights and creates one zone per sensor. Configure no longer asks for
rooms or weights.

Config entry version 3. Migrating from 2 turns each room sensor into a
one-sensor zone with its comfort weight and the sensor's entity ID as
the zone key, so learned models, forecast entities (now linked to their
zone, so deleting a zone removes them) and accuracy statistics carry
over. Older versions cannot load a version 3 entry; rolling back needs
the HA backup.

A zone learns only across polls that used the same sensors (a sensor
dropping out shifts the mean by its offset); the new poll outcome
"sensors_changed" reports this. Status renames: input_quality.zones
(per-sensor detail nested), excluded_zones, retired_zone_models; adds
zone_names. Invalid stored comfort weights now fall back to 1.0, so the
invalid_weights status is gone.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-27 02:32:11 +02:00
buzeraandClaude Opus 5.5 3076beebfb Leave out unusable rooms instead of pausing; add keep-last-value option
A single stale, unavailable, missing or invalid room sensor paused
learning and forecasts for every room. That is not acceptable once the
MPC may control heating.

Now such a room is left out: the weighted temperature, learning and the
optimizer use the remaining rooms with their weights re-normalized, and
a room learns only across poll pairs where it was usable at both ends.
Readiness considers only the rooms used. Everything pauses only when no
room is usable or a shared input (relay, thermostat, outdoor
temperature) is missing.

A new setup/Configure checkbox, room_stale_use_last_value (default off),
keeps using a stale room sensor's last value instead, for sensors that
report only on change. It never applies to unavailable or invalid
sensors, or to a sensor silent for more than 24 hours.

Status adds excluded_rooms, weight_coverage and a per-room "used" flag.
English and Romanian labels and help text added.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-26 22:07:18 +02:00
buzeraandClaude Opus 5.5 30f78fb6a9 Allow clearing optional weather sources in Options
Optional weather source fields used the current selection as the form
default. A cleared field that the frontend omits was refilled with the
old sources by voluptuous, and an options key missing from the
submission fell back to the original setup data. Optional providers
could therefore not be removed in the UI.

Pre-fill with suggested values instead, and save omitted optional lists
as empty so they override older entry data. No UI strings changed.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-26 21:21:38 +02:00
buzera cea79b6b48 Add sensor freshness checks 2026-10-26 18:13:00 +02:00
buzera 2b9a10979b initial commit v0.2.1 2026-10-26 17:34:32 +02:00