Commit Graph
4 Commits
Author SHA1 Message Date
buzeraandClaude Opus 5.5 d2bd398a0f Show learning activity with Learning Progress and Last Sample sensors
During a first test the Status entity only said "learning" for the
first half hour (the radiator-lag wait after a restart), and the
attributes explaining why were hard to find. Add two sensors:

- Learning Progress (%): for the least trained room, the mean of its
  three readiness requirements (200 samples, 30 ON, 30 OFF), each capped
  at 100 %; 100 % means ready. Attributes show the counts.
- Last Sample: an enum of the last poll's learning outcome, with English
  and Romanian state names (e.g. "Waiting for radiators to settle"). Its
  history shows when learning happens.

Polls blocked by missing shared inputs now report waiting_for_inputs.
Readiness thresholds move to const.py.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-26 22:39:25 +02:00
buzeraandClaude Opus 5.5 3076beebfb Leave out unusable rooms instead of pausing; add keep-last-value option
A single stale, unavailable, missing or invalid room sensor paused
learning and forecasts for every room. That is not acceptable once the
MPC may control heating.

Now such a room is left out: the weighted temperature, learning and the
optimizer use the remaining rooms with their weights re-normalized, and
a room learns only across poll pairs where it was usable at both ends.
Readiness considers only the rooms used. Everything pauses only when no
room is usable or a shared input (relay, thermostat, outdoor
temperature) is missing.

A new setup/Configure checkbox, room_stale_use_last_value (default off),
keeps using a stale room sensor's last value instead, for sensors that
report only on change. It never applies to unavailable or invalid
sensors, or to a sensor silent for more than 24 hours.

Status adds excluded_rooms, weight_coverage and a per-room "used" flag.
English and Romanian labels and help text added.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-26 22:07:18 +02:00
buzeraandClaude Opus 5.5 4daba5028b Show each sensor's longest report gap; stop recording volatile attributes
Choosing room and weather freshness limits required knowing how long
each sensor normally goes without reporting, which HA does not show.
Add max_age_seconds_24h to every source in input_quality: the largest
report age seen at polls over the last 24 hours (hourly buckets, reset
on reload, underestimates by up to one poll interval).

input_quality and weather_comparison change every poll, so the Recorder
stored a new attribute row every five minutes. Mark them unrecorded;
they remain visible on the Status entity. Model coefficients and other
attributes are still recorded.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-26 21:51:35 +02:00
buzera cea79b6b48 Add sensor freshness checks 2026-10-26 18:13:00 +02:00