buzeraandClaude Opus 5.5 099c63cd02 Recalibrate only the model parts whose configuration changed
Confirmed: learned models were matched only by zone key, so replacing a
zone's sensors, changing sensor weights, moving or replacing a heat
source or turning a window kept coefficients learned for a different
configuration, silently.

compatibility.py fingerprints exactly what each learned component
depends on: the zone measurement (sensors and relative weights; equal
scaling changes nothing), each zone's heat sources, the neighbour's
measurement, the zone's windows, window orientation (direction term
only), the recovery time (recovery only) and other zones' openings
(cross term only). Comfort weight, target offset and names are not
included. Heat-source baselines have their own fingerprint (sensor and
included sources).

On restore, a changed measurement recalibrates the zone: base and
extended loss/heat/bias keep their values as a warm start, but their
uncertainty, counts and readiness start over, other terms return to the
prior, and the zone's forecast statistics are dropped. Otherwise only
the changed terms are reset; everything else, including other zones,
is kept. Each recalibration is logged (Status model_changes, info log)
and saved at once. Data from before fingerprints (0.4.0) is assumed to
match its current configuration and is fingerprinted at the first
start, so the next edit is detected even before a learned sample.

Tests cover comfort changes, sensor replacement and weights, window
orientation and size, moved and replaced heat sources, re-added zones,
0.4.0 data and a second restart, plus an HA Core test through real
subentry updates.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-27 03:35:11 +02:00
buzeraandClaude Opus 5.5 00e70c612b Model electrical heat sources (UPS, gaming PC) per zone
Electrical equipment heats its room, and a gaming session can add
hundreds of watts, which the 3-parameter model attributed to the boiler
or the bias term.

heat_sources.py adds heat sources as config subentries ("Add heat
source"): an active-power sensor (W/kW; VA and % rejected), the zone,
the share that becomes heat, an automatic baseline (20th percentile of
24 h, so the persistent UPS load is not double counted with the bias
term) or a manual one, an optional "included in" parent (the UPS total
minus a separately measured PC, one level deep) and a first-order
thermal response time. The heat during each interval is the power held
from its start, like the radiator lag. After startup or an outage a
source's response must run two time constants before it counts as
settled.

zone_model.py layers each zone: the base model is kept unchanged as the
fallback and comparison, and an extended FeatureLearner adds "internal"
(kW above baseline after the response) and neighbour coupling for
adjacent zones. It learns only intervals where all its inputs are
known, and is used for forecasts once as trained as the base. The
optimizer accepts a multi-zone step model; forecasts let extra power
fade to baseline with a configurable half-life (default 30 min).

On a synthetic office with thermostat cycling and gaming sessions the
extended model recovers the electrical, boiler and loss coefficients
within 10 %. Status lists each source's power, effective power,
baseline, variable and responding heat; models show the extended
coefficients with confidence. Saved models gain optional zone_models
and heat_sources keys.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-27 02:39:18 +02:00