Leave out unusable rooms instead of pausing; add keep-last-value option
A single stale, unavailable, missing or invalid room sensor paused learning and forecasts for every room. That is not acceptable once the MPC may control heating. Now such a room is left out: the weighted temperature, learning and the optimizer use the remaining rooms with their weights re-normalized, and a room learns only across poll pairs where it was usable at both ends. Readiness considers only the rooms used. Everything pauses only when no room is usable or a shared input (relay, thermostat, outdoor temperature) is missing. A new setup/Configure checkbox, room_stale_use_last_value (default off), keeps using a stale room sensor's last value instead, for sensors that report only on change. It never applies to unavailable or invalid sensors, or to a sensor silent for more than 24 hours. Status adds excluded_rooms, weight_coverage and a per-room "used" flag. English and Romanian labels and help text added. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This commit is contained in:
1 parent
cd8b65ac2f
commit
3076beebfb
10 files changed
+184
-34
No files matched your search
@@ -10,7 +10,11 @@
|
||||
"heater_entity": "Physical heating switch (read-only)",
|
||||
"room_entities": "Individual room temperature sensors",
|
||||
"room_max_age_minutes": "Maximum room sensor report age (minutes)",
|
||||
"weather_max_age_minutes": "Maximum weather sensor report age (minutes)"
|
||||
"weather_max_age_minutes": "Maximum weather sensor report age (minutes)",
|
||||
"room_stale_use_last_value": "Keep using the last value of a room sensor that stopped reporting"
|
||||
},
|
||||
"data_description": {
|
||||
"room_stale_use_last_value": "Off: a room sensor older than its report-age limit is left out and the other rooms are re-weighted. On: its last value is still used, for up to 24 hours without a report; for sensors that report only when the value changes. Unavailable or invalid room sensors are always left out. Nothing pauses unless no room is usable."
|
||||
}
|
||||
},
|
||||
"weather": {
|
||||
@@ -63,7 +67,11 @@
|
||||
"heating_cost": "Heating runtime cost",
|
||||
"comfort_band": "Comfort tolerance (°C)",
|
||||
"room_max_age_minutes": "Maximum room sensor report age (minutes)",
|
||||
"weather_max_age_minutes": "Maximum weather sensor report age (minutes)"
|
||||
"weather_max_age_minutes": "Maximum weather sensor report age (minutes)",
|
||||
"room_stale_use_last_value": "Keep using the last value of a room sensor that stopped reporting"
|
||||
},
|
||||
"data_description": {
|
||||
"room_stale_use_last_value": "Off: a room sensor older than its report-age limit is left out and the other rooms are re-weighted. On: its last value is still used, for up to 24 hours without a report; for sensors that report only when the value changes. Unavailable or invalid room sensors are always left out. Nothing pauses unless no room is usable."
|
||||
}
|
||||
},
|
||||