# Heating MPC 0.2.1 — custom integration for Home Assistant OS
|
||||
|
||||
**Experimental, observation-only (shadow mode).** It **never** changes the Generic Thermostat, the physical relay, the boiler's setpoint, `heat/off`, or Comfort/Away/Sleep. No Docker add-on, MQTT or InfluxDB connection is needed.
|
||||
|
||||
This project targets Home Assistant OS on a Raspberry Pi 5, with one existing ON/OFF central-heating relay, `generic_thermostat`, and individual indoor temperature sensors.
|
||||
|
||||
## Install / upgrade
|
||||
|
||||
1. Create a Home Assistant backup.
|
||||
2. Copy the entire folder `custom_components/heating_mpc` into `/config/custom_components/heating_mpc` (replace its contents when upgrading from v0.1.0).
|
||||
3. Restart Home Assistant **Core**.
|
||||
4. If new: **Settings → Devices & services → Add integration → Heating MPC**. If installed already: select **Heating MPC → Configure** (Options).
|
||||
5. Choose the existing thermostat and physical heating switch (read-only), then individual room sensor entities.
|
||||
6. Choose *ordered lists* of **outdoor sensor entity IDs**. First valid sensor is active; if missing, unavailable, nonnumeric or outside reasonable bounds, the next valid sensor is used automatically.
|
||||
7. Assign a relative comfort weight (0.1–10) to each selected room.
|
||||
|
||||
**No entity IDs are hard-coded.** Every room and outdoor measurement can be changed later via **Configure**, without editing YAML or Python.
|
||||
|
||||
## Reconfigurable weather inputs
|
||||
|
||||
| Measurement | Required? | Used in the thermal model in 0.2.0? |
|
||||
|---|---|---|
|
||||
| Outdoor temperature | **Yes** (1–10 prioritized sensors) | **Yes**: estimates thermal losses; constant over the 2 h forecast window |
|
||||
| Wind speed | No | No, diagnostics/source comparison only |
|
||||
| Cloud cover | No | No, diagnostics/source comparison only |
|
||||
| Humidity | No | No, diagnostics/source comparison only |
|
||||
| Feels-like temperature | No | No, diagnostics/source comparison only |
|
||||
| Atmospheric pressure | No | No, diagnostics/source comparison only |
|
||||
| Visibility | No | No, diagnostics/source comparison only |
|
||||
| Rain / snow | No | No, diagnostics/source comparison only |
|
||||
|
||||
Choose multiple sensors for a single variable, e.g. OpenWeatherMap then another provider, in priority order. Switch order in **Configure** to run A/B comparisons on successive days, or simply let the second sensor act as fallback. The active source and all current alternative readings are visible in the **Heating MPC Status** entity attributes (`weather`, `weather_active_sources`, `weather_comparison`). The **MPC Outdoor Temperature** sensor also has an `active_source` attribute and an `alternatives` map.
|
||||
|
||||
Measurements are normalized where possible: outdoor temperatures to °C; wind to m/s; pressure to hPa; visibility to meters. Unknown units or values outside plausibility bounds are rejected in favor of the next selected sensor. Clouds and humidity are expected in %, rain/snow in mm or mm/h as represented by their upstream sensor. A fallback source may have a different sampling delay; no stale-data age policy exists yet.
|
||||
|
||||
Switching only the **weather-provider sensors** does not reset learned thermal parameters. The update is applied after the integration reloads, and it skips learning one transition when the primary temperature source changes, avoiding a jump in the training series. Nevertheless, two sensors with a persistent offset can bias predictions; compare their readings and validate the model again before relying on them. Replacing the physical heating switch discards incompatible model parameters. Existing room-specific parameters are retained if room entity IDs remain unchanged.
|
||||
|
||||
## Model, sampling and output
|
||||
|
||||
- Every 5 minutes: reads HA sensor states and observed relay state; learns a per-room linear thermal model `dT = a*(T_out-T_room) + b*effective_heating + c`.
|
||||
- Learns only from valid 5-minute transitions; uses a smoothed heating-demand proxy to approximate radiator lag.
|
||||
- After at least 200 transitions and samples with both heating states, runs an ON/OFF MPC search for the next 60–180 minutes (default 120) in 15-minute command blocks. Protects against rapid simulated toggling.
|
||||
- Uses room comfort weights and the **existing** Generic Thermostat's target and heat/off state. **The simulated ON/OFF demand never operates hardware**.
|
||||
- Persists model parameters using HA's `.storage` so HA restarts do not discard the trained data.
|
||||
|
||||
Entities (entity IDs may vary):
|
||||
|
||||
- `sensor.heating_mpc_status` — learning/ready/paused status and diagnostics, including outside weather, active source, all valid alternative weather values, model coefficients, proposed 15-minute plan.
|
||||
- `sensor.heating_mpc_weighted_temperature` — own room-weighted average, informative only.
|
||||
- `sensor.mpc_outdoor_temperature` — selected external temp and alternatives.
|
||||
- Per-room predicted temperatures after 60 minutes.
|
||||
- `binary_sensor.heating_mpc_proposed_heat` — **hypothetical** heating demand (unavailable until ready).
|
||||
|
||||
## Known limitations / safety
|
||||
|
||||
- **Do not** connect the proposed binary sensor directly to the heating switch or build an automation from it. A production controller would need watchdog, manual override, safety handling, and an exclusive relay owner with Generic Thermostat fallback.
|
||||
- The other meteorological variables besides temperature are intentionally **captured but not yet fitted into the thermal model**. This allows source tests without falsely treating weak inputs as validated improvements. Later versions can test whether wind or solar proxy reduces held-out forecast error.
|
||||
- All rooms share one heating actuator. The model does not command individual radiators.
|
||||
- No weather forecast: assumes outdoor temperature remains constant during simulated horizon.
|
||||
- No Recorder/InfluxDB training backfill. It learns only from samples collected after installation.
|
||||
- The demand switch is not a burner-flame or real gas consumption measurement.
|
||||
- Full HAOS/UI runtime integration has **not** been tested; Python/model/unit/source tests are offline checks only.
|
||||
- Home Assistant Core APIs and config-flow selectors can change; take a backup before trying this experimental custom integration.
|
||||
|
||||
## Offline tests
|
||||
|
||||
```bash
|
||||
python -m unittest discover -s tests -v
|
||||
```
|
||||
|
||||
## v0.2.1: integration visibility and clean uninstall
|
||||
|
||||
- Corrects the manifest classification from `helper` to `service`. Existing config entries should move from the Helpers listing to **Settings → Devices & services → Integrations** after replacing the files and restarting Home Assistant Core. No deletion/reconfiguration is needed to upgrade.
|
||||
- When the integration config entry is deleted from the Integrations page, Home Assistant removes its registered entities, and `async_remove_entry` removes the locally persisted learned-model data (`.storage/heating_mpc.<entry_id>`). The custom component source folder remains on disk until manually removed.
|
||||
- MPC behavior is otherwise unchanged and remains read-only / shadow-only.
|
||||